Journal Basic Info

  • Impact Factor: 0.285**
  • H-Index: 6
  • ISSN: 2638-4558
  • DOI: 10.25107/2638-4558
**Impact Factor calculated based on Google Scholar Citations. Please contact us for any more details.

Major Scope

  •  Autism
  •  Transplantation Medicine
  •  Nuclear Medicine
  •  Epidemiology
  •  Breast Neoplasms
  •  Pulmonary Medicine
  •  Dermatology and Cosmetology
  •  Neurology

Abstract

Citation: Clin Case Rep Int. 2024;8(1):1671.DOI: 10.25107/2638-4558.1671

Application of Thyroid Cartilage Recording Electrode for Intraoperative Neuromonitoring During Giant Retrosternal Goiter Surgery

Zhang M, Shao G, Sun B, Shi M, Wang X, Song Y, Zhang G and Li G

Collage of Chinese Medicine, Shandong University of Traditional Chinese Medicine, China
Department of Thyroid and Breast Diagnosis and Treatment Center, Weifang Hospital of Traditional Chinese Medicine, China
Department of Ophthalmology, Affiliated Hospital of Weifang Medical University, China
These authors have contributed equally to this work and share first authorship

*Correspondance to: Guangdong Shao 

 PDF  Full Text Case Report | Open Access

Abstract:

Background: At present, the vocal cord surface contact electrode attached to the endotracheal tube is the mainstream device at the receiving end of the intraoperative neuromonitoring system. However, the application is often limited in patients with difficult airway caused by the oppression of a huge goiter. Methods: A 66-year-old man from China came to our department because of the compression, displacement and deformation of trachea caused by huge retrosternal goiter. Our preoperative evaluation found that it was difficult to insert a traditional endotracheal tube with surface electrodes in his condition. Thus, we selected the thyroid cartilage recording electrodes to monitor the neural signals and reduce the probability of recurrent laryngeal nerve injury during the surgery. Results: The lesion in this patient was completely excised, along with complete protection of the recurrent laryngeal nerve and vagus nerve. There were no complications, such as hoarseness, coughing upon drinking water, and dyspnea after the operation, the patient recovered well. Conclusion: The intraoperative neuromonitoring system technique using thyroid cartilage recording electrodes was an effective method for reducing recurrent laryngeal nerve injury during giant retrosternal goiter surgery.

Keywords:

Giant retrosternal goiter; Intraoperative neuromonitoring; Thyroid cartilage recording electrode; Recurrent laryngeal nerve injury

Cite the Article:

Zhang M, Shao G, Sun B, Shi M, Wang X, Song Y, et al. Application of Thyroid Cartilage Recording Electrode for Intraoperative Neuromonitoring During Giant Retrosternal Goiter Surgery. Clin Case Rep Int. 2024; 8: 1671.

Search Our Journal

Journal Indexed In

Articles with Grants

Environmental Risk Factors Contributing to the Transmission of COVID-19 in Zambia: A Cross-Sectional Study in Lusaka District
 Abstract  PDF  Full Text
Sinus Elevation for Implant Placement Leading to Implant Failure and Natural Tooth Extraction: A Case Report
 Abstract  PDF  Full Text
View More...